2. Product Name and Specifications
2.1. Name and Model
Name: Inductively coupled plasma mass spectrometer
Model: ICP-MS 2000
2.2. Manufacturer: Jiangsu Skyray Instrument Co., LTD
2.3. Working Condition
Working temperature: 15-30℃
Power supply: AC 220±5V (Remarks: the power supply also can be 110±5V)
2.4. Technical Performance and Specifications
2.4.1 Solid state Generator
Integral 1600W solid state crystal controlled 27MHz ICP-MS generator. A dynamic real time tuning system
ensures optimum matching of RF load even during changes in sample solvent composition.
1. Circuit type: solid-state RF power supply, with function of auto match.
2. Solid state generator Frequency: 27.12MHz
3. Power Output: 500 W ~1600 W
4. Power requirement: 220V, 30A
5. Shield Torch system
2.4.2 Sample introduction
The standard sample introduction system includes an efficient, low-flow concentric nebulizer, a temperature controlled spray chamber and a high precision peristaltic pump.
1. Inlet system: Unique, opening design, easy to install and demount sampling kit with peltier cooling technology
2. Peristaltic pump:Computer speed controlled 3 channels pump
3. Nebulizer:Glass concentric nebulizer
4. Torch: 1.5 mm quartz torch
5. Computer controlled adjustment of the single piece, self-locating torch in the X, Y and Z planes.
2.4.3 Ion Lenses
1. Off-axis lens
2. Extraction lens
2.4.4 Filtration and detection system
High performance quadrupole analyzer provides excellent transmission and abundance sensitivity across the full mass range.
1.mass range:2~255 amu
2.Dynamic linear range:109
3.Resolution:0.6~0.8 amu (PC controlled switchable, quadrupole resolution settings)
6.SNR(Signal to Noise Ratio):≥50×106
7.Background noise:2 cps(all mass number range)
8.Mass axis stability:0.05 amu/24 h
14. Easy to install and demount nickel sampling and skimmer cones.
15. Collision cell technology for optimized interference reduction.
16. Ion filtration: Demountable Molybdenum quadrupole180 mm×12 mm equipped with pre-quadrupole system20mm×12mm.
17. Quadrupole RF generator:Solid state frequency:2.0 MHz
18. Unique three stage vacuum design comprising of a single rotary pump and a sight high performance turbo pump.
19. Detector:Discrete dynode electron multiplier detector provides greater than 9 orders of dynamic range via simultaneous analog/ pulse counting detection.
2.4.5 Mass 2000 software.
Version 2.00 version software provides seamless control of the ICP-MS 2000 and accessories.
User-friendly interface and optimized function setting provide the best operation experience.
2.4.6 ICP-MS 2000 Auto sampler
1. 60X 4 sample rack
2. High throughput sampling. Fast up-taking and rinsing system
3. Peripherals of ICP-MS 2000(Optional and charged additionally)
3.1 Computer
1.1 Configuration: OS – Windows 7 or Up
1.2 Memory: 2G or better
1.3 Monitor: 17” SVGA LCD
1.4 HD: 500G or more
1.5 DVD-ROM: 24X or more
1.6 CPU: Inter Core i3 or above
1.7 USB Port: 4 or more
3.2 Color Ink-Jet Printer
3.3 Regulated Power Supply
3.3.1 Function: To provide stable and reliable power supply to the instrument.
3.3.2 Optional models
1. Purified AC regulated power supply
2. Online UPS
4. Spare parts and accessories
4.1. Quartz Torch
4.2 2.5mm ID quartz injector
4.3 Spray chamber
4.4 Sampling and Skimmer cone
4.5 Peristaltic pump
4.6 Sampling tube. Peristaltic pump tube. Drain tube.
4.7 Argon gas regulator valve
4.8 Peltier cooling kit
4.9 Clamp, torch ball joint connector
4.10 Cover of the instrument
5. Necessary Technical Documents Enclosed:
5.1 Operation Manual
5.2 A List of the Parts
5.3 Inspection Report
5.4 CE certificate